The Custom Tabular tool of OpUtils enables you define a set of OIDs that have to be queried on demand and show its current value. The tool can be used to query any SNMP-enabled device to view its current value.
Select Add Custom Tool link from the Custom Tool category from the Tools tab. This opens the Add Custom Tool page.
Provide a name for the tool.
Select the Type as "Tabular". This option is selected by default.
Select the MIB from the MIB Name combo box and click Show. You can use the Add MIB button to add the MIBs to the MIB Name combo box. This lists all the scalar and tabular nodes of the selected MIB.
Select the Scalar Node or Tabular Column Node tabs to view the MIB nodes of that type.
Click Add>> link to add the required nodes.
Repeat steps 5 and 6 to add nodes from other MIBs
After adding all the required nodes, click Create Tool button.
The tool gets created and added under the Custom Tools category in the Tools tab.
Click the name of the tool available under the Custom Tools category in the Tool tab.
Specify the device name and its SNMP community string in the respective fields.
Click Scan.
Check the results. The details of the MIB Nodes along with their current values are grouped and shown in a tabular format.
To delete a custom tool, click the delete icon available next to the tool name in the Tools tab.