AD Replication Manager helps you:
In order to download AD Replication Manager, go to this link, and click on the Download button.
To know more about the steps to configure AD Replication Manager, visit this website.
ocal Users Manager helps you:
In order to download Local Users Manager, go to this link, and click on the Download button.
To know more about the steps to configure Local Users Manager, visit this website.
To retrieve the local user accounts of multiple computers
The Empty Password Reporter helps you list all AD user accounts that do not have passwords (password attribute value set to null).
In order to download Empty Password Reporter, go to this link, and click on the Download button.
To know more about the steps to configure Empty Password Reporter, visit this website.
This tool helps you send password expiry notifications to users. These notifications are automated and can be sent via SMS, emails or push notifications.
In order to download Password Expiration Notifier, go to this link and click on the Download button.
Visit this website to know how to configure the Password Expiration Notifier.
Weak Password Users Reports help identify all the users whose passwords are weak or do not adhere to the password policies of your organization.
In order to download Weak Password Users Report, go to this link, and click on the Download button.
The Weak Password Reporter compares the hashes of the passwords specified in the PasswordPatterns.txt file with the hashes of the passwords of AD users. If any of the hashes match, then the corresponding user is listed in the Weak Password Users report.
To know more about the steps to configure Weak Password Users Report, visit this website.
The PST Migration Tool helps:
In order to download PST Migration Tool, go to this link, and click on the Download button.
To know more about the steps to configure the PST Misgration Tool, visit this website.
This Tool enables you to generate a full-fledged CSV file with a comprehensive attribute list by providing a very simple CSV file (say a CSV with sAMAccountName) as input.
In order to download the CSV Generator, go to this link, and click on the Download button.
To know more about the steps to configure the CSV Generator Tool, visit this website.
Why do I need the Service Accounts Management Tool?
In order to download Service Accounts Management Tool, go to this link, and click on the Download button.
To know more about the steps to configure the Service Accounts Management Tool, visit this website.
This tool helps identify the roles of different domain controllers in a specific domain.
In order to download Domain Controller Roles Reporter, go to this link, and click on the Download button.
To know more about the steps to configure the Domian Controller Roles Reporter, visit this website.
This tool helps you gain valuable insights about your network such as DNS records, IP addresses, server's services and more.
In order to download DNS Reporter, go to this link, and click on the Download button.
To know more about the steps to configure the DNS Reporter, visit this website.
This tool helps you identify the duplicate entries of all Active Directory object attributes.
In order to download Duplicates Identifier, go to this link, and click on the Download button.
To know more about the steps to configure the Duplicates Identifier, visit this website.
This tool helps list the different Domain Controllers in a domain and helps monitor performance by listing essential information such as CPU utilization, disk utilization and memory utilization.
In order to download the Domain Controller Monitoring Tool, go to this link, and click on the Download button.
To know more about the steps to configure the Domain Controller Monitoring Tool, visit this website.
This tool enables you to analyze the status of all the ports that are used by third-party applications accessing Active Directory.
In order to download DMZ Port Analyzer, go to this link, and click on the Download button.
The ports that can be checked by the DMZ Port Analyzer are:
To know more about the steps to configure the DMZ Port Analyzer, visit this website.
This tool helps identify and manage multiple terminal sessions from a single point in a domain.
In order to download Terminal Session Manager, go to this link, and click on the Download button.
To know more about the steps to configure the Terminal Session Management Tool, visit this website.
This tool enables you to identify the last logon time of Active Directory users in a specific domain.
In order to download Last Logon Reporter, go to this link, and click on the Download button.
To know more about the steps to configure the Last Logon Reporter, visit this website.
This tool provides you with an easy-to-use GUI for querying Microsoft Active Directory.
In order to download Active Directory Query Tool, go to this link, and click on the Download button.
Note: The Advanced option helps generate more attribute results for the domain with respect to the specified query.
To know more about the steps to configure the Active Directory Query Tool, visit this website.
To know more about the steps to configure the Active Directory Query Tool, visit this website.
The Password Policy Manager enables:
In order to download Password Policy Manager, go to this link, and click on the Download button.
NOTE: Only administrators or users with administrative rights can change a password policy. Others can only view the policy.
To know more about the steps to configure the Password Policy Manager, visit this website.
Yes. Network discovery script is helpful to displays the discovery status of the devices in a network.
https://resources.manageengine.com/resources/resource/network-discovery-powershell-script
Please check Dot Net Platform is installed in your system. Run the utility available in the bin directory, Check_Dot_Net_version.exe , It will tell you the Dot Net version. If Dot Net platform is not available in the system, download the platform.
You can monitor upto 10 servers simultaneously. To monitor more servers please visit http://www.manageengine.com/network-monitoring or send mail to freetools-support@manageengine.com
Yes, the refresh interval for the ping and web response can be modified under the settings.
Yes, The Free Ping Tool can monitor external websites also. (Provided the servers /websites are reachable)
No, we don't have this option in this tool. To get SMS or Email alerts, please try OpManager or send mail to freetools-support@manageengine.com
Access to the path is Denied:
Check whether the User Access Control settings is 'Always Notify' or 'Never Notify'. If Always notify, it doesn't have the privilege to write/modify file operation under the location C:\Program Files (x86). Hence, Tool throws 'Access Denied' error.
Try one of the following:
Try our Powershell script (UACChangerScript) to change the UAC settings in local and remote machine.
https://resources.manageengine.com/resources/resource/change-user-access-control-uac-using-powershell-powershell-script
Usage : .\UACChangerScript.ps1 -computernames localhost
Please check host server is running properly and check host server is behind firewall and also port 443 is accessible. If the server is behind firewall and if not accessible, then open the port by configuring firewall.
Please check Dot Net Platform is installed in your system. Run the utility available in the bin directory, Check_Dot_Net_version.exe , It will tell you the Dot Net version. If Dot Net platform is not available in the system, download the platform. Please see the software requirements page for downloading the platform.
Yes, 1 server alone can also be monitored. However, the tool can monitor upto 2 servers simultaneously.
To monitor more server. please visit http://www.manageengine.com/opmanager or send mail to freetools-support@manageengine.com
No, Automatic email alerts are not supported in this tool. You may try our Applications Manager http://www.manageengine.com/products/applications_manager/vmware-monitoring.html
By default, the VMWare Server runs on Port 443. Port field is optional.
You can download and install Microsoft .Net framework 4.0 from here
443 is the default port. Port number field is optional.
It indicates how much of disk or data store used space the VHD/VMDK file occupies.
The tool connects to the local host by default. If VMware is enabled in localhost, delete it from the server list and add the localhost again.
The error occurs when "DCOM configuration" is not enabled in the remote machine.
From your remote device, Goto Run, type dcomcnfg and hit enter. Double click on Console Root --> Component Services --> Computers --> My Computer. Right click and click on properties. Select Default Properties tab in the pop-up window and check 'Enable Distributed Computer on this computer'. Try connecting to the remote server again after enabling this setting.
(or)
Run our Remote Dcom Enabler script, enables the Dcom access and launch the activation for the specific user account.
Note: Refer the user guide for detailed instruction on the same
This problem can be due to either one of the below reasons.
You can download and install Microsoft .Net framework 3.5 from here.
XenServer Tools must be installed in all the VM's you are interested in monitoring, then only you will be able to get the metrics(otherwise XenServer won't collect the performance metrics) for the VMs.
This problem can be due to either one of the below reasons.
Yes. You can get this feature by downloading the essential version of Opmanager.
Please check host server is running properly and check host server is behind firewall and also port 443 is accessible. If the server is behind firewall and if not accessible, then open the port by configuring firewall.
Please check Dot Net Platform is installed in your system. Run the utility available in the bin directory, DotNetUtilities.exe, It will tell you the Dot Net version. If Dot Net platform is not available in the system, download the platform. Please see the software requirements page for downloading the platform.
Tool monitors 3 server simultaneously. Yes, 1 server alone can be monitored also.
Some Windows services depend on other services to start or stop. So the tool displays the dependent services and tries to stop or start these services. However any of these services is dependent on some other services, the tool displays a message showing that these services needs to be started or stopped, before trying to start or stop the main services.
Windows operating system will not allow some services to stop . Hence it automatically restarts those services.
To monitor more servers simultaneously please visit http://www.manageengine.com/network-monitoring or send mail to freetools-support@manageengine.com
Try reconnecting to the device.
"2147024891 (Access is Denied)"This error could be due to either one of the below reasons.
So disable the firewall and then try to connect using the administrator credentials. If the problem still persists send a mail to freetools-support@manageengine.com
The error occurs when "DCOM configuration" is not enabled in the remote machine.
From your remote device, Goto Run, type dcomcnfg and hit enter. Double click on Console Root --> Component Services --> Computers --> My Computer. Right click and click on properties. Select Default Properties tab in the pop-up window and check 'Enable Distributed Computer on this computer'. Try connecting to the remote server again after enabling this setting.
(or)
Run our Remote Dcom Enabler script, enables the Dcom access and launch the activation for the specific user account.
Note: Refer the user guide for detailed instruction on the same
The error occurs when "DCOM configuration" is not enabled in the remote machine.
From your remote device, Goto Run, type dcomcnfg and hit enter. Double click on Console Root --> Component Services --> Computers --> My Computer. Right click and click on properties. Select Default Properties tab in the pop-up window and check 'Enable Distributed Computer on this computer'. Try connecting to the remote server again after enabling this setting.
(or)
Run our Remote Dcom Enabler script, enables the Dcom access and launch the activation for the specific user account.
Note: Refer the user guide for detailed instruction on the same
This problem can be due to either one of the below reasons.
You can download and install Microsoft .Net framework 4.0 from here
This problem might be due to issues in WMI services running in the remote machine. Restarting the remote machine's WMI service might fix the issue. To restart the WMI service, from your remote machine go to Start/run, type services.msc and press Enter. In the services window find Windows Management Instrumentation service and restart it.
The Error occurs when .Net Framework version is below 4.0. Please install the Microsoft Visual C++ Redistributable package (x86) and run the Free Windows Health Monitor.
You can download and install Microsoft Visual C++ Redistributable package (x86) from here
Windows operating system will not allow some services to stop . Hence it automatically restarts those services.
This Error occurs when .Net Framework version is below 4.0. Install the Microsoft Visual C++ Redistributable package (x86) and then run the tool again.
You can download and install Microsoft Visual C++ Redistributable package (x86) from here
From your remote device, Goto Run, type dcomcnfg and hit enter. Double click on Console Root --> Component Services --> Computers --> My Computer. Right click and click on properties. Select Default Properties tab in the pop-up window and check 'Enable Distributed Computer on this computer'. Try connecting to the remote server again after enabling this setting. If the issue still persists send a mail to freetools-support@manageengine.com
For error in server:
Open a command prompt on the target machine that you want to monitor and run the following command, For Windows 2000 winmgmt /resyncperf (To clear all WMI-related values from the service's performance registry key.)
For other Windows OS wmiadap /f
For error in client:
Try re-creating the WMI repository,(To be done in the machine where Windows health monitor is installed)
No need to worry about the repository folder, this will be recreated when you restart the computer in step 9.
Possible reasons for RPC server unavailable:
Access to the path is Denied:
Check whether the User Access Control settings is 'Always Notify' or 'Never Notify'. If Always Notify, it doesn't have the privilege to write/modify file operation under the location C:\Program Files (x86). Hence, Tool throws 'Access Denied' error.
Try one of the following:
Try our Powershell script (UACChangerScript) to change the UAC settings in local and remote machine.
https://resources.manageengine.com/resources/resource/change-user-access-control-uac-using-powershell-powershell-script
Usage : .\UACChangerScript.ps1 -computernames localhost
Please check the server is running properly and check the server is behind firewall and also port 445 and 135 is accessible. if the server is behind firewall and if not accessible, then open the port by configuring firewall.
Please check Dot Net platform is installed in your system. Run the utility available in the bin directory, Check_Dot_Net_version.exe , It will tell you the Dot Net version. If Dot Net platform is not available in the system, download the platform. Please see the software requirements page for downloading the platform.
Please check the following steps.
If you are getting (No error) the Windows Management Instrumentation Tester Dialog with the Enum Classes, Enum Instances, Open Namespace.etc., buttons enabled, then you can able to connect to the server. If you are getting error message then check your credentials and also ensure that wmi and RPC services are running properly in remote machine.
To monitor more servers, please visit //www.manageengine.com/network-monitoring/download.html or send mail to freetools-support@manageengine.com
This Error occurs when .Net Framework version is below 4.0. Install the Microsoft Visual C++ Redistributable package (x86) and then run the tool again.
You can download and install Microsoft Visual C++ Redistributable package (x86) from here
The error occurs when "DCOM configuration" is not enabled in the remote machine.
From your remote device, Goto Run, type dcomcnfg and hit enter. Double click on Console Root --> Component Services --> Computers --> My Computer. Right click and click on properties. Select Default Properties tab in the pop-up window and check 'Enable Distributed Computer on this computer'. Try connecting to the remote server again after enabling this setting.
(or)
Run our Remote Dcom Enabler script, enables the Dcom access and launch the activation for the specific user account.
Note: Refer the user guide for detailed instruction on the same
Possible reasons for RPC server unavailable:
Yes. ManageEngine has powershell script to backup the SQL DB details.
https://resources.manageengine.com/resources/resource/sqldbbackup-powershell-script/
This problem occurs if the host server is behind the firewall or if port 445 is not accessible. (note: open the port by configuring firewall.)
Please check if the Dot Net Platform is installed in your system. Run the utility available in the bin directory, DotNetUtilities.exe, It will tell you the Dot Net version. If Dot Net platform is not available in the system, download the platform. (note: Please see the software requirements page for downloading the platform.)
It uses Windows administrator credentials to fetch the SQL Server performance metrics.
Server name : Machine name or IP Address of the SQL Server installed system.
Domain Name : If the server is inside a domain, please specify.
Instance name : Instance Name of the SQL Server. For default (MSSQLSERVER) instance, leave it empty.
Username and password : Windows administrator credentials of the Server
You can monitor 2 servers simultaneously. To monitor more server please visit - http://www.manageengine.com/products/applications_manager/sql/index.html or send mail to freetools-support@manageengine.com
This error could be due to either one of the below reasons.
Try reconnecting to the device. If you are still unable to connect, try the following steps and send the outcome of the test to freetools-support@manageengine.com
The error occurs when "DCOM configuration" is not enabled in the remote machine.
From your remote device, Goto Run, type dcomcnfg and hit enter. Double click on Console Root --> Component Services --> Computers --> My Computer. Right click and click on properties. Select Default Properties tab in the pop-up window and check 'Enable Distributed Computer on this computer'. Try connecting to the remote server again after enabling this setting.
(or)
Run our Remote Dcom Enabler script, enables the Dcom access and launch the activation for the specific user account.
Note: Refer the user guide for detailed instruction on the same
To confirm if SNMP service is running on the device, Go to Windows Services (services.msc) and see if the 'SNMP Service' status shows running. If not, start the service.
Check whether a community is configured in the SNMP agent, Right click the SNMP service --> Click Properties --> Go to Security tab --> see community value. If the value is not defined, add the community default as public and click "OK" button. Then give the defined community in MibBrowser.
(or)
Try our poweshell script to add or set the SNMP Agent community on remote /local machine.
Usage : .\SNMPEnabler.ps1 -h
https://resources.manageengine.com/resources/resource/snmp-enabler-powershell-script
Also, check "Accept SNMP Packets from any Host " or "Accept SNMP Packets from defined Hosts" radio button
Goto ManageEngine Mibbrowser, Click "Debug" icon or View --> Debug, which receives the incoming and outgoing SNMP packets. You can decode the Hex PDU packets to human readable format using "Decode" button. It also helps to decode the SNMP packets in file format.
Yes you can. The tool itself is bundled with Java Runtime Environment (JRE) which runs the MibBrowser (java) application. Hence, installing java in your machine is not required.
The SnmpString class accepts Hex strings in a certain format. Any string that starts and ends with a single quote(') is interpreted as an Hex string. The individual bytes should be separated using a colon(:). For example, if you need to enter 0x2a304cab, it should be supplied as '2a:30:4c:ab'.
To Troubleshoot the timeout error,
If queried agent is "Windows SNMP Agent"
Fill the write community value in the textfield. By default 'Write community' as empty. Check the values of agent running Host Name, Port and Community values. Incorrect values return timeout error.
Yes. MibBrowser support the polling for integer Object Identifier. Load RFC 1213 Mib --> Select IfNumber--> Click Line graph icon from the tool bar (View --> Line Graph).
For Tabular node, Click Table and "Start Polling" . It updates the values in a table Periodically, poll interval is specified in table settings window.
The Hex values should start with a 0x or 0X. Therefore, if you set a value for contextID or contextName, it should be 0xHHHHHH.
Timeout value should be given in seconds. If you give the timeout value in milliseconds, it takes much time to get timed out. For example, a value of 1000 waits for 1000 seconds.
Retry value should be integer . Retries is the number of times a request is sent when a timeout occurs. If the retry value is 0, the request is re-transmitted on timeout.
To create a new row in a table:
If RowStatus is not present in the table definition, you can only modify the existing row by double-clicking the corresponding cell in the table.
Before making any request, the host name or the IP address of the machine in which the agent is running should be specified in the "Host" text field of MibBrowser.
To load multiple MIBs, files should be separated by a blank space and be given within double quotes. For example,
java MibBrowserApplication -m "mibs/RFC1213-MIB mibs/RFC1271-MIB mibs/RFC1155-MIB" -h localhost -c public
The number of rows you get back may be limited by the PDU size permitted by your agent, manager, or transport.
By default the trap browser starts in the port 162. If the port is reserved or if the port is already used by some application this error will occur. You can restart the trap browser by giving the port no of any unused port.
Enable the the "Load recently loaded Mibs at startup" check box in the MibSettings window of the MibBrowser.
Edit ---> Settings --->MibSettings ---> Enable Load recently loaded Mibs at startup checkbox.
Yes, ManageEngine MibBrowser - Script Rule Engine allows script configuration defined by the user. It supports python and batch scripts for Windows.
To Configure Script, Click on the Script Icon available on the tool bar.
Yes, Refer online JavaDocs for custom class.
Custom class implements ScriptHandler and should defined in com.adventnet.snmp.scripting package.
Compile the java file in any of the following ways :
(or)
Now the compiled customized classes will be present in <ProductHome>\classes directory.
Script action logs are saved in the directory <product_home>\logs\scriptlog.txt
Go to MIB Browser install location.
By default, MibBrowser loads the mibs in "compiled file" Mibloading option.
Compiled mode loads the mibs from .cmi and .cds file. Mibbrowser parses the mibs and creates .cds and .cmi at first time. Then it loads the mibs from .cmi and .cds directly without doing parsing.
If user wants to edit the existing mibs and load the modified mibs, they should delete the existing .cmi and .cds file in the mibs directory. For example, load the modified RFC1213-MIB, delete the existing RFC1213-MIB.cmi and RFC1213-MIB.cds file.
(or)
Change the MibLoading option as "Direct" or "Overwrite Existing Compiled MIB Files" . MibBrowser Settings --> Direct.
MibBrowser Settings --> Overwrite existing Compiled MIB Files.
In this case, it loads the modified mibs directly.
Refer the Mibloading Option to know more details.
Check whether, you have full privilege to write the file in the location "C:\Program Files (x86)\ManageEngine\MibBrowser Free Tool\mibs". While loading the mibs in the MibBrowser, it parses the mibs and generates the .cmi and .cds file under the same location (C:\Program Files (x86)\ManageEngine\MibBrowser Free Tool\mibs). If the .cds and .cmi files are written in the same location successfully, then it loads the corresponding mibs in the MibBrowser. If file writes operation fails, it returns the error "Could not find the file" and backend returns the "Problem in opening the file".
Follow, any one of the below steps to resolve the issue:
Check UAC settings Level
Try our Powershell script (UACChangerScript) to view and modify the UAC Settings Level in the Local and Remote machine.
https://resources.manageengine.com/resources/resource/change-user-access-control-uac-using-powershell-powershell-script
Usage : .\UACChangerScript.ps1 -computernames localhost
Yes. Network discovery script is helpful to displays the discovery status of the devices in a network.
https://resources.manageengine.com/resources/resource/network-discovery-powershell-script/
Check whether .Net platform is installed in your system. The tool requires Microsoft .NET Framework 3.5 for running. The bin directory of the tool is provided with a utility 'DotNetUtilities.exe'. Run this utility from the command prompt to find the .Netversion installed in your system. You can download and install Microsoft .Net framework 3.5 from here.
This exception will be thrown when Winpcap is not installed in your machine. Download the latest version of winpcap. Check the software requirements page for the downloading link.
If any interface comes up while tool is running, it will be updated on click of the start button (ie) if any interface comes up, to update the same, click Stop and then Start.
If you are facing any error while running the tool ,please send us mail to freetools-support@manageengine.com
Check the following:
If the server is behind firewall and still not accessible, then open the port by configuring the firewall.
Please check Dot Net platform is installed in your system. Run the utility available in the bin directory, Check_Dot_Net_version.exe , It will tell you the Dot Net version. If Dot Net platform is not available in the system, download the platform. Please see the software requirements page for downloading the platform.
Yes. You can monitor upto 2 hyper-v servers.
Based on the Percentage CPU Utilization and CPU Threshold values, the tool will show the alert signals on the Dashboard to intimate status to the user.
Yes. You can generate real-time performance reports of hosts and VMs as a pdf document.
You can also save and print the report.
Possible reasons for RPC server unavailable:
The error occurs when "DCOM configuration" is not enabled in the remote machine.
From your remote device, Goto Run, type dcomcnfg and hit enter. Double click on Console Root --> Component Services --> Computers --> My Computer. Right click and click on properties. Select Default Properties tab in the pop-up window and check 'Enable Distributed Computer on this computer'. Try connecting to the remote server again after enabling this setting.
(or)
Run our Remote Dcom Enabler script, enables the Dcom access and launch the activation for the specific user account.
Note: Refer the user guide for detailed instruction on the same
Please check whether the Dot Net platform is installed in your system. Run the utility available in the bin directory, DotNetUtilities.exe, it will inform you the Dot Net version. If Dot Net platform is not available in your system, download the platform. This tool requires Dot Net Version 4 for it to run successfully. So please see the software requirements page for downloading the platform.
You need to enable the "Enable Diagnostics" check box in your Azure cloud service project. While creating cloud service related package or deploying the cloud service using third party software, you need to add the counter details to be monitored. Then you can monitor your environment with this tool.
To check the availability of Enable diagnostics of cloud service in the Azure Management portal,
Yes. You can monitor only one azure account.
Yes. You can monitor all the roles deployed in an environment
Go to Azure management portal then select the "Cloud services" tab. Select any one of the cloud services from the list.
Click the "Configure tab" and check the storage account name and key in Diagnostics Connection Strings
Azure Performance Monitor Tool supports the azure sdk version up to 2.5.
Please check if the host server is running properly ; check if the host server is behind firewall and also if port 443 is accessible. If the server is behind firewall and if not accessible, then open the port by configuring firewall.
Please check Dot Net platform is installed in your system. Run the utility available in the bin directory, DotNetUtilities.exe , It will tell you the Dot Net version. If Dot Net platform is not available in the system, download the platform. Please see the software requirements page for downloading the platform.
Changes made on any VM of a VMware ESX Host may be reverted, if the Host is being managed by a VCenter Server.
To monitor more servers, please visithttp://www.manageengine.com/network-monitoring/vmware-monitoring.html or send mail to freetools-support@manageengine.com
Please check whether the Dot Net platform is installed in your system. Run the utility available in the bin directory, DotNetUtilities.exe , it will tell you the Dot Net version. If Dot Net platform is not available in the system, download the platform. Please see the software requirements page for downloading the platform.
Yes, you can view more than one mode of data retrieval at any given instance. If you click "historical data", historical data will be active in the main window. Again, if you select "Live feed data" it will start live feed polling.
Yes, you can monitor more than one instance using EC2 Health Monitor Tool. If you select a instance in the tree, tool will populate the performance metrics for that instance. Any instance can be selected for monitoring.
Asia Pacific (Sydney), Asia Pacific (Tokyo), Asia Pacific (Singapore), EU (Ireland), South America (Sao Paulo), US East (N. Virginia),US West (N. California), US West (Oregon)
Please check Dot Net Platform is installed in your system. Run the utility available in the bin directory, DotNetUtilities.exe, it will tell you the Dot Net version. If Dot Net platform is not available in the system, download the platform. Please see the software requirements page for downloading the platform.
The Syslog listening port specified is occupied by some other process. So please stop the process and start the Free Syslog Forwarder Tool.
Yes you can. Refer document section for this.
The Free Syslog Forwarder Tool will process 2000 messages per second, but it may vary depending upon the server. The process includes receiving, filtering and forwarding the syslog message.
You can forward messages upto 10 servers simultaneously.
To confirm if SNMP service is running on the device, Go to Windows Services (services.msc) and see if the 'SNMP Service' status shows running. If not, start the service.
Check whether a community is configured in the SNMP agent, Right click the SNMP service --> Click Properties --> Go to Security tab --> see community value. If the value is not defined, add the community default as public and click "OK" button. Then give the defined community in MibBrowser.
(or)
Try our poweshell script to add or set the SNMP Agent community on remote /local machine.
Usage : .\SNMPEnabler.ps1 -h
https://resources.manageengine.com/resources/resource/snmp-enabler-powershell-script
Also, check "Accept SNMP Packets from any Host " or "Accept SNMP Packets from defined Hosts" radio button
Please check if Dot Net Platform is installed in your system. Run the utility available in the bin directory, DotNetUtilities.exe. It will inform you the Dot Net version. If Dot Net platform is not available in the system, download the platform. Please see the software requirements page for downloading the platform.
Yes, you can enable multiple servers simultaneously. You can enable multiple servers by either selecting the servers one by one or by clicking on the check box at the top to select all servers at one go.
To confirm if SNMP service is running on the device, Go to Windows Services (services.msc) and see if the 'SNMP Service' status shows running. If not, start the service.
Check whether community is configured in the snmp agent , Right click the SNMP service --> Click Properties --> Go to Security tab --> see community value. If the value is not defined , add the community default as public and click "OK" button community as . Then give the defined community in MibBrowser.
Also, check "Accept SNMP Packets from any Host " or "Accept SNMP Packets from defined Hosts" radio button.
Yes, the installation timeout can be modified between 90 and 600 secs.
Yes, the batch count value can be modified between 3 and 15 counts.
Yes. You can add more than one server using import option in the settings and adding the servers in bulk from a text file.
The Endpoint Central Free Windows tools are free to use. No hidden cost anywhere. The product can be used for free both for personal and business use.
Yes, the product can be redistributed AS IS with appropriate credits. However, you need to get prior approval from us stating the reason for redistribution. Contact free-tools@desktopcentral.com for getting the approval
Yes, you will get technical support through Email and Forums. The tec hnical support is free and you do not have to pay for it.
The Access Denied error is shown for any of the following reasons:
The RPC Server Unavailable error is shown in the following cases:
Active directory Tools