Troubleshooting
Network path not found: Error code 35/53
Cause
This error occurs when the PDC's SYSVOL share is not accessible from the ADAudit Plus server.
Troubleshooting
- Ping the PDC by its flat name and fully qualified domain name (FQDN) from the ADAudit Plus server.
- Open File Explorer on the ADAudit Plus server and access the SYSVOL folder using your PDC's flat name and FQDN (\\PDC Name\sysvol).
- If you are not able to access it, append the DNS suffix on the ADAudit Plus server either by adding an entry in the Advanced TCP/IP Settings or by adding a host record on the DNS server and mapping this name to the server's IP address .
- Ensure that the RPC ports (static port 135 and dynamic ports 49152–65535) are open. Follow this port guide to open the required RPC ports.
- Enable the agent-based GPO watcher to avoid all network errors:
- Open ADAudit Plus.
- Go to Admin > Configuration > GPO settings changes.
- Enable the Watch via agent option.
- Click Save.
Network access denied: Error code 65/41
Cause
This error occurs when the configured user does not have read access to the SYSVOL folder.
Troubleshooting
- Enable hardened UNC paths:
- Confirm that the user configured in the ADAudit Plus console has read permissions over the following share: \\<PDC Name>\SysVol\<Domain Name>\Policies\
- If they have read permissions, open the Local Group Policy Editor on the ADAudit Plus server (gpedit.msc).
- Go to Computer Configuration > Administrative Templates > Network > Network Provider.
- Double-click Hardened UNC Paths and click Enabled.
- In the Options section, scroll down and click Show.
- Add the following entry:
- Under the Value name column, type the following:\\*\SYSVOL
- Under the Value column, type the following: RequireMutualAuthentication=0,RequireIntegrity=0,RequirePrivacy=0
- Click OK.
- Enable the agent-based GPO watcher to avoid all network errors:
- Open ADAudit Plus.
- Go to Admin > Configuration > GPO settings changes.
- Enable the Watch via agent option.
- Click Save.
The RPC server is unavailable: Error code 6ba
Cause
This error occurs when the RPC ports (static port 135 and dynamic ports 49152–65535) are not opened in the firewall.
Troubleshooting
- Follow this port guide to open the RPC ports required for the ADAudit Plus server to access the target machine.
- Enable the agent-based GPO watcher to avoid all network errors:
- Open ADAudit Plus.
- Go to Admin > Configuration > GPO settings changes.
- Enable the Watch via agent option.
- Click Save.
Don't see what you're looking for?
-
Visit our community
Post your questions in the forum.
-
Request additional resources
Send us your requirements.
-
Need implementation assistance?
Try OnboardPro